Technical Details
​
Total chlorine measuring range (different versions)
â– 0.01...20.0 mg/l
â– pH range 5.5...9.5
â– Temperature 5…45 ºC
â– Pressure max. 3.0 bar
Sensor for Total Chlorine CTE 2-mA​
Long-term stable sensor for total chlorine, including free chlorine and chloramine. Reliable measurement result even at a high pH value in various waters. For use on controllers with mA input.​
​
Your Benefits
â– Measured variables: Total chlorine, chlorine compounds in which chlorine acts as an oxidising substance, e.g. free chlorine (HOCl and OCl-),
chloramines, etc.
â– Improved measurement accuracy due to equalisation of the sensitivities for free and combined chlorine
â– Increased long-term stability due to membrane-covered sensor with innovative membrane design. This also prevents interference from changing
flow rates or water constituents
â– Hydrophilic membrane ensures permeability for different water-soluble oxidising agents to the measuring electrode
â– Special reaction system of the electrolyte enables the determination of components that contain oxidising chlorine as well as use at high pH of up
to 9.5​
​
Sensor for Total Chlorine CTE 2-CAN​
Long-term stable sensor for total chlorine, including free chlorine and chloramines. Reliable measurement even at high pH values in various waters. For operation with measuring and control devices with CAN bus connection
Your Benefits
â– Measured variables: Total chlorine, chlorine compounds in which chlorine acts as an oxidising substance, e.g. free chlorine (HOCl and OCl-),
chloramines, etc.
â– Improved measurement accuracy due to equalisation of the sensitivities for free and combined chlorine
â– Increased long-term stability due to membrane-covered sensor with innovative membrane design. This also prevents interference caused by
changing flow rates or water constituents
â– Hydrophilic membrane ensures permeability for different water-soluble oxidising agents to the measuring electrode
â– Special reaction system of the electrolyte enables the determination of components containing oxidising chlorine as well as use at high pH of up
to 9.5
â– Operation on the CAN bus with all the associated advantages
​
Sensor for Total Chlorine CTE 3-mA
​
Long-term stable sensor for total chlorine, including free chlorine and chloramine. Fault-free use in inline electrolysis (tubular cell electrolysis). Reliable measurement result even at a high pH value in various waters. For use on controllers with mA input.
​
Your Benefits
​
â– Measured variables: Total chlorine, chlorine compounds, in which chlorine acts as an oxidising agent, e.g. free chlorine (HOCl and OCl-),
chloramines etc.
â– Suited to determining the combined chlorine (total chlorine minus free chlorine) in the pool & wellness industry when inline electrolysis (tubular cell
electrolysis) is used for chlorination
â– Improved measurement accuracy by adjusting sensitivity levels for free and combined chlorine
â– Minimal dependence on flow and avoidance of interference caused by substances in the water as the measuring electrodes are protected by an
innovative diaphragm system.
â– Hydrophilic diaphragm guarantees permeability for different water-soluble oxidising agents towards the measuring electrodes
■The special reaction system of the electrolyte allows components containing oxidising chlorine to be determined and used at a high pH of up to 9.5​​
​
Sensor for Total Chlorine CTE 3-CAN​
Long-term stable sensor for total chlorine, including free chlorine and chloramine. Fault-free use in inline electrolysis (tubular cell electrolysis) in the pool & wellness industry by optimising the working electrode. Reliable measurement result even at a high pH value. For use on controllers with
CAN-bus connection
Your Benefits
â– Measured variables: Total chlorine, chlorine compounds, in which chlorine acts as an oxidising agent, e.g. free chlorine (HOCl and OCl-),
chloramines etc.
â– Suited to determining the combined chlorine (total chlorine minus free chlorine) in the pool & wellness industry when inline electrolysis (tubular
cell electrolysis) is used for chlorination
â– Improved measurement accuracy by adjusting sensitivity levels for free and combined chlorine
â– Minimal dependence on flow and avoidance of interference caused by substances in the water as the measuring electrodes are protected by an
innovative diaphragm system
â– Hydrophilic diaphragm guarantees permeability for different water-soluble oxidising agents towards the measuring electrodes
â– The special reaction system of the electrolyte allows components containing oxidising chlorine to be determined and used at a high pH of up to 9.5
■Operation on the CAN-bus with all the associated benefits​
​
Sensor for Total Chlorine CTE 1-mA​
Sensor for total chlorine, including, for example, free chlorine, chloramines etc. even with high pH values in different kinds of water. For use on controllers with mA input.
​
Your Benefits
â– Measured variable: Total chlorine, chlorine compounds, in which chlorine acts as an oxidising agent, e.g. free chlorine (HOCl and OCl-),
chloramines etc.​
â– Diaphragm-covered sensor (encapsulated) prevents faults caused by changing flow or ingredients in the water
â– Hydrophilic diaphragm guarantees permeability for different water-soluble oxidising agents towards the measuring electrodes
■The special reaction system of the electrolyte allows components containing oxidising chlorine to be determined and used at a high pH of up to 9.5​
​
Chlorine sensors complete with 50 ml of electrolyte
A mounting kit, order no. 815079, is required for initial fitting of the chlorine sensors in the in-line probe housing DLG III.​
​
Sensor for Total Chlorine CTE 1-DMT​
Sensor for total chlorine, including, for example, free chlorine, chloramines etc. even with high pH values in different kinds of water. For operation with the transmitter DMT
​
Your Benefits
â– Measured variable: Total chlorine, chlorine compounds, in which chlorine acts as an oxidising agent, e.g. free chlorine (HOCl and OCl-),
chloramines etc.
â– Diaphragm-covered sensor (encapsulated) prevents faults caused by changing flow or ingredients in the water
â– Hydrophilic diaphragm guarantees permeability for different water-soluble oxidising agents towards the measuring electrodes
â– The special reaction system of the electrolyte allows components containing oxidising chlorine to be determined and used at a high pH of up to 9.5
​
Chlorine sensors complete with 50 ml of electrolyte
A mounting kit, order no. 815079, is required for initial fitting of the chlorine sensors in the in-line probe housing DLG III.
​
Sensor for Total Chlorine CTE 1-CAN​
Sensor for total chlorine, including, for example, free chlorine, chloramines etc. even with high pH values in different kinds of water. For use on controllers with CAN-bus connection
​
Your Benefits
â– Measured variable: Total chlorine, chlorine compounds, in which chlorine acts as an oxidising agent, e.g. free chlorine (HOCl and OCl-),
chloramines etc.
â– Diaphragm-covered sensor (encapsulated) prevents faults caused by changing flow or ingredients in the water
â– Hydrophilic diaphragm guarantees permeability for different water-soluble oxidising agents towards the measuring electrodes
â– The special reaction system of the electrolyte allows components containing oxidising chlorine to be determined and used at a high pH of up to 9.5
■Operation on the CAN-bus with all the associated benefits​
​
Chlorine sensors complete with 100 ml of electrolyte
A mounting kit, order no. 815079, is required for initial fitting of the chlorine sensors in the in-line probe housing DLG III.
​​