Technical Details
​
â– CLE 3; pH: 5.5 … 8.0; Temp. 5 … 45 °C
â– CLE3.1; pH: 5.5 … 8.0; Temp. 5 … 45 °C
â– CLO 3; pH: 5.0 … 9.0; Temp. 5 … 45 °C
â– CLO 4; pH: 5.0 … 9.0; Temp. 5 … 70 °C
â– CLB 4; pH: 5.0 … 9.0; Temp. 5 … 45 °C
â– CLB 5; pH: 5.0 … 9.0; Temp. 5 … 45 °C
â– CBR 1; pH: 5.0 … 9.5; Temp. 5 … 45 °C
â– CLR 1; pH: 5.5 … 8.0; Temp. 5 … 45 °C​
​
Sensor for Free Chlorine CLE 3-mA
Standard sensor for measuring free chlorine in clear water. For operation on controllers with 4-20 mA input.
Your Benefits
â– Measured variable: free chlorine, no significant cross-sensitivity to combined chlorine (chloramines)
â– Diaphragm-covered sensor (encapsulated) minimises faults caused by changing flow or substances in the water
Chlorine sensors complete with 100 ml of electrolyte
A mounting kit, order no. 815079, is required for initial fitting of the chlorine sensors in the in-line probe housing DLG III.
​
Sensor for Free Chlorine CLE 3.1-mA
Standard sensor for measuring free chlorine in clear water. For operation on controllers with 4-20 mA input
Your Benefits
â– Measured variable: free chlorine, no cross-sensitivity to combined chlorine (chloramines), even if there is an excess of it
â– Diaphragm-covered sensor (encapsulated) minimises faults caused by changing flow or substances in the water
Chlorine sensors complete with 100 ml of electrolyte
A mounting kit, order no. 815079, is required for initial fitting of the chlorine sensors in the in-line probe housing DLG III.
​
Sensor for Free Chlorine CLE 3-DMT
Standard sensor for measuring free chlorine in clear water. For operation on ProMinent transmitters type DMT
​
Your Benefits
â– Measured variable: free chlorine, no significant cross-sensitivity to combined chlorine (chloramines)
â– Diaphragm-covered sensor (encapsulated) minimises faults caused by changing flow or substances in the water
​
Chlorine sensors complete with 100 ml of electrolyte
A mounting kit, order no. 815079, is required for initial fitting of the chlorine sensors in the in-line probe housing DLG III.
Sensor for Free Chlorine CLE 3-CAN
Standard sensor for measuring free chlorine in clear water. For use on controllers with CAN-bus connection.
​
Your Benefits
â– Measured variable: free chlorine, no significant cross-sensitivity to combined chlorine (chloramines)
â– Diaphragm-covered sensor (encapsulated) minimises faults caused by changing flow or substances in the water
Chlorine sensors complete with 100 ml of electrolyte
A mounting kit, order no. 815079, is required for initial fitting of the chlorine sensors in the in-line probe housing DLG III.
​
Sensor for Free Chlorine CLE 3.1-CAN
Sensor for the measurement of free chlorine in clear water with higher selectivity towards combined chlorine. For use on controllers with CAN-bus connection
Your Benefits
â– Measured variable: free chlorine, no cross-sensitivity to combined chlorine (chloramines) even if there is an excess of it
â– Diaphragm-covered sensor (encapsulated) minimises faults caused by changing flow or substances in the water
â– Operation on the CAN-bus with all the associated benefits
​
Chlorine sensors complete with 100 ml of electrolyte
A mounting kit, order no. 815079, is required for initial fitting of the chlorine sensors in the in-line probe housing DLG III.
​
Sensor for Free Chlorine CLO 3-mA
Sensor for the measurement of free chlorine in clear water, as well as in seawater, and when using electrolysis processes for disinfection, up to 45 °C (1 bar) or 8 bar (25 °C). For operation with controllers with 4-20 mA input. Also suitable for use in film-forming water with optional "hydrodynamic cleaning".
​
Your Benefits
â– Measured variable: free chlorine, no significant cross-sensitivity to combined chlorine (chloramines)
â– Use when sample water is returned to the process line
â– Use at higher pressures
â– Avoidance of problems caused by electrolysis systems in which the electrodes are immersed directly into the sample water
â– Measurement of free chlorine up to pH 9
â– Measurement in seawater possible
â– Also suitable for use in film-forming water with optional "hydrodynamic cleaning".
​
Sensor for Free Chlorine CLO 3-CAN​
Sensor for the measurement of free chlorine in clear water even when using electrolysis processes for disinfection, up to 45 °C (1 bar) or 8 bar (25 °C). For use on controllers with CAN-bus connection. Also suitable for use in film-forming water with optional “hydrodynamic cleaning”.
​
Your Benefits
â– Measured variable: free chlorine, no significant cross-sensitivity to combined chlorine (chloramines)
â– Use when sample water is returned to the process line
â– Use at higher pressures
â– Avoidance of problems caused by electrolysis systems in which the electrodes are immersed directly into the sample water
â– Measurement in seawater possible
â– Also suitable for use in film-forming water with optional "hydrodynamic cleaning".
​
Sensor for Free Chlorine CLO 4-mA​
Sensor for the measurement of free chlorine in clear water, as well as in seawater, and when using electrolysis processes for disinfection, up to 70 °C or 8 bar (25 °C). For operation with controllers with 4-20 mA input. Also suitable for use in film-forming water with optional "hydrodynamic cleaning".
​
Your Benefits
â– Measured variable: free chlorine, no significant cross-sensitivity to combined chlorine (chloramines)
â– Use when sample water is returned to the process line
â– Use at higher pressures/temperatures
â– Avoidance of problems caused by electrolysis systems in which the electrodes are immersed directly into the sample water
â– Measurement of free chlorine up to pH 9
â– Measurement in seawater possible
â– Also suitable for use in film-forming water with optional "hydrodynamic cleaning"
​
Sensor for Free Chlorine CLB 4-µA
Cost-effective, simple sensor for the measurement of free chlorine in clear water, also in seawater and with a changing media temperature. Can also be used with electrolysis processes for disinfection at up to 45 °C/3 bar. For operation with the Compact controller DCCa​
​
Your Benefits
â– Measured variable: free chlorine, no significant cross-sensitivity to combined chlorine (chloramines)
â– Cost-effective due to its simple construction without separate wear parts
â– Simple, cost-effective maintenance without handling of the diaphragm caps
â– Avoidance of problems caused by electrolysis systems without a diaphragm in which the electrodes are immersed directly into the sample water
â– Measurement of free chlorine up to pH 9 and use at high pressure of up to 3 bar thanks to absence of a diaphragm
â– Measurement in seawater possible
​
Sensor for Free Chlorine CLB 5-µA​
Cost-effective, simple sensor for the measurement of free chlorine in clear water, also in seawater and with a constant media temperature. Can also be used with electrolysis processes for disinfection at up to 45 °C/3 bar. For operation with the Compact controller DCCa
​
Your Benefits
â– Measured variable: free chlorine, no significant cross-sensitivity to combined chlorine (chloramines)
â– Cost-effective due to its simple construction without separate wear parts
â– Simple, cost-effective maintenance without handling of the diaphragm caps
â– Avoidance of problems caused by electrolysis systems without a diaphragm in which the electrodes are immersed directly into the sample water
â– Measurement of free chlorine up to pH 9 and use at high pressure of up to 3 bar thanks to absence of a diaphragm
■Measurement in seawater possible​
​
Sensor for Free Chlorine CBR 1-mA​
Sensor for free chlorine and bromine in contaminated water, also suitable for high pH values of up to 9.5. For use with controllers with 4-20 mA input
​
Your Benefits
â– Measured variable: free chlorine, as well as free and combined bromine (bromamines)
â– Diaphragm-covered sensor minimises faults caused by changing flow or ingredients in the water
â– Resistance to films of dirt and biofilms by electrolyte with antimicrobial effect and large-pore diaphragm
â– Use at high pH value of up to 9.5 by optimisation of the electrolyte diaphragm system
​
* Measuring range based on chlorine. When measuring bromine, the lower and upper limit of the measuring range are increased by the factor 2.25, therefore for example CBR 1-mA-0.5ppm: 0.02 ...1.1 ppm.
Sensor for Free Chlorine CBR 1-CAN​​
Sensor for free chlorine and bromine in contaminated water, also suitable for high pH values of up to 9.5. For use on controllers with CAN-bus connection.
​
Your Benefits
â– Measured variable: free chlorine as well as free and combined bromine (bromamines)
â– Diaphragm-covered sensor minimises faults caused by changing flow or ingredients in the water
â– Resistance to films of dirt and biofilms by electrolyte with antimicrobial effect and large-pore diaphragm
â– Use at high pH value of up to 9.5 by optimisation of the electrolyte diaphragm system
​
Sensor for Free Chlorine CLR 1-mA​​
Sensor for free chlorine above 10 ppm in contaminated washing water for use with controllers with 4-20 mA input
​
Your Benefits
â– Measured variable free chlorine for high concentrations of up to 1,000 ppm
â– Diaphragm-covered sensor prevents faults caused by changing flow or ingredients in the water
â– Resistance to films of dirt by pore-free diaphragm
​
A mounting kit, order no. 815079, is required for initial fitting of the chlorine sensors in the in-line probe housing DLG III.