top of page

Conductivity Sensor LMP 001​

Sensor for measuring extremely low electrolytic conductivities in clear water, including water contaminated with chemicals. Features integrated temperature measurement and a DIN 4-plug.

​

Your Benefits​

â–     Measured variable: electrolytic conductivity above 0.01 µS/cm

â–     Cost-effective sensor for clear, chemically contaminated water

â–      Integrated Pt 100 for temperature compensation replaces separate temperature sensor and the corresponding sensor fitting

Conductivity Sensor LMP 001-HT

​

Sensor for measuring extremely low electrolytic conductivity in clear water, including water contaminated with chemicals. Designed for high temperatures, with integrated temperature measurement and a DIN 4-plug.

​

Your Benefits

â–     Measured variable: electrolytic conductivity above 0.01 µS/cm

â–     Cost-effective sensor for clear, chemically contaminated water

â–     Integrated Pt 100 for temperature compensation replaces separate temperature sensor and the corresponding sensor fitting

â–     Temperature resistance up to 100 °C

​

Conductivity Sensor LMP 01​​

Sensor for measuring low electrolytic conductivities in clear water, including water contaminated with chemicals. Features integrated temperature measurement and a DIN 4-plug.

​

Your Benefits

â–     Measured variable: electrolytic conductivity above 0.1 µS/cm

â–     Cost-effective sensor for clear, chemically contaminated water

â–     Integrated Pt 100 for temperature compensation replaces separate temperature sensor and the corresponding sensor fitting

​

Conductivity Sensor LMP 01-TA

Sensor for measurement of low electrolytic conductivities in clear water, including water contaminated with chemicals. Features integrated temperature measurement and a DIN 4-plug

​

Your Benefits

â–     Measured variable: electrolytic conductivity above 0.1 µS/cm

â–     Cost-effective sensor for clear, chemically contaminated water

â–     Simple installation in tanks and containers by sensor ready mounted in the immersion tube

â–     Integrated Pt 100 for temperature compensation replaces separate temperature sensor and the corresponding sensor fitting

​

Conductivity Sensor LMP 01-HT

Sensor for measuring low electrolytic conductivities in clear water, including water contaminated with chemicals. Designed for high temperatures, with integrated temperature measurement and a DIN 4-plug

​

Your Benefits

â–     Measured variable: electrolytic conductivity above 0.1 µm/cm

â–     Cost-effective sensor for clear, chemically contaminated water

â–     Temperature resistance up to 100 °C

â–     Integrated Pt 100 for temperature compensation replaces separate temperature sensor and the corresponding sensor fitting

​

Conductivity Sensor Conductivity Sensor LFT 1 FE

Affordable sensor for measuring electrolytic conductivity in clear, uncontaminated water. Features integrated temperature measurement and a hardwired connection

​

Your Benefits

â–     Measured variable: electrolytic conductivity above 10 µS/cm

â–     Cost-effective sensor for all clear uncontaminated water

â–     Flexible process connection by the use of sensor fittings for standard pH sensors

â–     Special graphite electrodes, optimised for a highly dynamic measuring range: 0.01-20 mS/cm

â–     Integrated Pt 100 for temperature compensation replaces separate temperature sensor and the corresponding sensor fitting

â–     Fixed cable on the sensor head for difficult ambient conditions

​

Conductivity Sensor LFTK 1 FE-5m-shd

Affordable sensor for measuring electrolytic conductivity in clear, uncontaminated water. Features integrated temperature measurement and a fixed cable connection (5 m)

​

Your Benefits

â–     Measured variable: electrolytic conductivity above 10 µS/cm

â–     Cost-effective sensor for all clear uncontaminated water

â–     Flexible process connection by the use of sensor fittings for standard pH sensors

â–     Special graphite electrodes, optimised for a highly dynamic measuring range: 0.01-20 mS/cm

â–     Integrated Pt 1000 for precise temperature compensation in limited temperature ranges replaces separate temperature sensor and the

      corresponding sensor fitting

â–     Fixed cable on the sensor head for difficult ambient conditions

​

Conductivity Sensor LFTK 1 FE-3m-shd

Affordable sensor for measuring electrolytic conductivity in clear, uncontaminated water. Features integrated temperature measurement and a fixed cable connection (3 m)

​

Your Benefits

â–     Measured variable: electrolytic conductivity above 10 µS/cm

â–     Cost-effective sensor for all clear uncontaminated water

â–     Flexible process connection by the use of sensor fittings for standard pH sensors

â–     Special graphite electrodes, optimised for a highly dynamic measuring range: 0.01-20 mS/cm

â–     Integrated Pt 1000 for precise temperature compensation in limited temperature ranges replaces separate temperature sensor and the

      corresponding sensor fitting

â–     Fixed cable on the sensor head for difficult ambient conditions

​

Conductivity Sensor LFT 1 DE

Affordable sensor for measuring electrolytic conductivity in clear, uncontaminated water. Features integrated temperature measurement and a
DIN 4-plug

​

Your Benefits

â–     Measured variable: electrolytic conductivity above 10 µS/cm

â–     Cost-effective sensor for all clear, uncontaminated types of water

â–     Flexible process connection by the use of sensor fittings for standard pH sensors

â–     Special graphite electrodes, optimised for a highly dynamic measuring range: 0.01-20 mS/cm

â–     Integrated Pt 100 for temperature compensation replaces separate temperature sensor and the corresponding sensor fitting

â–     DIN 4-pin plug for simple installation

​

Conductivity Sensor LFTK 1 DE

Affordable sensor for measuring electrolytic conductivity in clear, uncontaminated water, with integrated temperature measurement and a DIN 4-plug

​

Your Benefits

â–     Measured variable: electrolytic conductivity above 10 µS/cm

â–     Cost-effective sensor for all clear uncontaminated water

â–     Flexible process connection by the use of sensor fittings for standard pH sensors

â–     Special graphite electrodes, optimised for a highly dynamic measuring range: 0.01-20 mS/cm

â–     Integrated Pt 100 for temperature compensation replaces separate temperature sensor and the corresponding sensor fitting

â–     DIN 4-pin plug for simple installation

​

Conductivity sensor LFT 1 1/2"

Affordable sensor for measuring electrolytic conductivity in clear, uncontaminated water. Features integrated temperature measurement, a DIN 4-plug, and a 1/2-inch screw-in thread

​

Your Benefits

â–     Measured variable: electrolytic conductivity above 10 µS/cm

â–     Cost-effective sensor for all clear, uncontaminated types of water

â–     Hydraulic connector with 1/2" thread as an alternative to the corresponding standard design with PG 13.5 thread

â–     Special graphite electrodes, optimised for a highly dynamic measuring range: 0.01-20 mS/cm

â–     Integrated Pt 100 for temperature compensation replaces separate temperature sensor and the corresponding sensor fitting

â–     DIN 4-pin plug for simple installation

​

Conductivity Sensor CK 1

Sensor for the measurement of electrolytic conductivity in clear, chemically contaminated water at higher but constant temperatures, with a DIN 4-plug

​

Your Benefits

â–     Measured variable: electrolytic conductivity above 10 µS/cm

â–     Resistant to water ingredients in target applications thanks to injection-moulded design without adhesive or seals

â–     High temperature resistance up to 135 °C

​

Conductivity Sensor CKPt 1

Sensor for measurement of electrolytic conductivity in clear, chemically contaminated water and at higher temperatures. Features integrated temperature measurement and a DIN 4-plug.

​

Your Benefits

â–     Measured variable: electrolytic conductivity above 10 µS/cm

â–     Resistant to water ingredients in target applications thanks to injection-moulded design without adhesive or seals

â–     High temperature resistance up to 135 °C

â–     Integrated Pt 100 for temperature compensation replaces separate temperature sensor and the corresponding sensor fitting

​

Conductivity Sensor LM 1

Sensor for the measurement of electrolytic conductivity in clear water, including water contaminated with chemicals. With DIN 4-plug​.

​

Your Benefits

â–     Measured variable: electrolytic conductivity above 0.1 mS/cm

â–     Cost-effective sensor for clear, chemically contaminated water

â–     Resistant to the constituents in the water of the target application

​

Conductivity Sensor LM 1-TA

Sensor for the measurement of electrolytic conductivity in clear water, including water contaminated with chemicals. Fully assembled in an immersion fitting

​

Your Benefits

â–     Measured variable: electrolytic conductivity above 0.1 mS/cm

â–     Cost-effective sensor for clear, chemically contaminated water

â–     Resistant to the ingredients in the water of the target applications

â–     Simple installation in tanks, containers etc. by sensor ready mounted in the immersion tube

​

Spare Parts

Conductivity Sensor LMP 1

Sensor for measuring electrolytic conductivity in clear water, including water contaminated with chemicals. Features integrated temperature measurement and a DIN 4-plug.

​

Your Benefits

â–     Measured variable: electrolytic conductivity above 0.1 mS/cm

â–     Cost-effective sensor for clear, chemically contaminated water

â–     Resistant to the ingredients in the water of the target applications

â–     Integrated Pt 100 for temperature compensation replaces separate temperature sensor and the corresponding sensor fitting

​

Conductivity Sensor LMP 1-TA

Sensor for measuring electrolytic conductivity in clear water, including water contaminated with chemicals. Features integrated temperature measurement and is fully assembled in an immersion fitting.

​

Your Benefits

â–     Measured variable: electrolytic conductivity above 0.1 mS/cm

â–     Cost-effective sensor for clear, chemically contaminated water

â–     Resistant to the ingredients in the water of the target applications

â–     Integrated Pt 100 for temperature compensation replaces separate temperature sensor and the corresponding sensor fitting

â–     Simple installation in tanks, containers etc. by sensor ready mounted in the immersion tube

​

Spare Parts

Conductivity Sensor LMP 1-HT

Sensor for measuring electrolytic conductivity in clear water, including water contaminated with chemicals. Designed for high temperatures, with integrated temperature measurement and a DIN 4-plug.

​

Your Benefits

â–     Measured variable: electrolytic conductivity above 0.1 mS/cm

â–     Cost-effective sensor for clear, chemically contaminated water

â–     Resistant to the ingredients in the water of the target applications

â–     Integrated Pt 100 for temperature compensation replaces separate temperature sensor and the corresponding sensor fitting

â–     Temperature resistance up to 100 °C

​

Conductivity sensor CCT 1-mA

Sensor for measurement of electrolytic conductivities for clear and also chemically contaminated water. With integrated temperature measurement and factory-calibrated 4...20 mA output signal.

​

Your Benefits

â–     Measured variable: electrolytic conductivity up to 100 mS/cm

â–     Fail-safe 4-20 mA output signal for flexible connection to measuring equipment with standard 4-20 mA input

â–     Integrated temperature sensor for temperature compensation replaces separate temperature sensor and the corresponding sensor fitting

â–     Simple connection to a process with the ProMinent bypass fittings BAMa, DGMA, DLGIII and INLI

​

Conductivity sensor ICT 5

Cost-effective inductive conductivity sensor, suitable for high electrolytic conductivities above 200 µS/cm. Also suitable for chemically contaminated water and film-forming media. For installation in pipework

​

Your Benefits

â–     Measured variable: electrolytic conductivity. The inductive (non-contact) measuring principle permits applications in chemically contaminated types

      of water and in film-forming media

â–     Complete with injection moulded PP sensor head, no apparent bonds, seals

â–     Measurements at high conductivity values of up to 2,000 mS/cm are possible without interfering polarisation by means of the high measuring range

      dynamics of the inductive measuring principle

â–     Simple installation in PVC pipework by bonding the DN 40 adhesive connector supplied into a standard T-piece and screwing in the sensor using the

      union nut supplied.

â–     A DN 40 welded connector is optionally available for use in PP pipework

​

Conductivity Sensor ICT 5-IMA

Cost-effective inductive conductivity sensor, suitable for high electrolytic conductivities above 200 µS/cm. Also suitable for chemically contaminated water and film-forming media. Completely integrated into an immersion pipe

​

Your Benefits

â–     Measured variable: electrolytic conductivity. The inductive (non-contact) measuring principle permits applications in chemically contaminated types

      of water and in film-forming media

â–     Complete with injection moulded PP sensor head, no apparent bonds, seals

â–     Measurements at high conductivity values of up to 2,000 mS/cm are possible without interfering polarisation by means of the high measuring range

      dynamics of the inductive measuring principle

â–     Simple installation in tanks, containers etc. thanks to sensor ready mounted in the immersion tube

​

Conductivity Sensor ICT 2

High-performance inductive conductivity sensor with high dynamic measuring range. Also suitable for types of water with aggressive chemicals and film-forming components. Permitted temperatures up to 125 °C. For installation in pipework, tanks and for immersion in storage tanks

​

Your Benefits

â–     Measured variable: electrolytic conductivity. The inductive (non-contact) measuring principle permits applications in chemically

      contaminated types of water and in film-forming media

â–     There is no need for adhesive or seals as the sensor is fully embedded in PFA

â–     Measurements at high conductivity values of up to 2,000 mS/cm are possible without interfering polarisation by means of the high

      measuring range dynamics of the inductive measuring principle

â–     Flexible connection to the processes is possible via a flange or immersion pipe with optional accessories

​

Conductivity sensor ICT 8-mA

Inductive sensor for the measurement of electrolytic conductivity. Suitable for contaminated water. With integrated temperature correction and factory-calibrated 4...20 mA output signal.

​

Your Benefits

â–     Measured variable: electrolytic conductivity. The inductive (non-contact) measuring principle permits applications in chemically contaminated types

      of water and in film-forming media

â–     There is no need for adhesive or seals as the sensor is fully embedded in PFA

â–     Measurements at high conductivity values of up to 2,000 mS/cm are possible without interfering polarisation by means of the high measuring range

      dynamics of the inductive measuring principle

â–     Flexible connection to the processes is possible via a flange or immersion pipe with optional accessories

​

Contact Us

ProMinent Australia

 

​​​​+61 2 9450 0995

​

​

​

envelope icon new.png
bottom of page