top of page

Technical Details​

​

Sensor type CDE 2-mA

â–     Measuring ranges 0.01…10 mg/l

â–     Temperature 5…45 °C

â–     Pressure max. 1.0 bar

â–     pH range 4.0…11.0

â–     Response time 120 s

​

Sensor type CDP 1-mA

â–     Measuring ranges 0.02…2.00 mg/l

â–     Temperature 10…45 °C

â–     Pressure max. 3.0 bar

â–     pH range 5.5…10.5

â–     Response time 60 s

​

Sensor type CDR 1-mA

â–     Measuring ranges 0.01…10.0 mg/l

â–     Temperature 1…55 °C

â–     Pressure max. 3.0 bar

â–     pH range 1.0…10.0

â–     Response time 180 s​​

​

Chlorine Dioxide Sensor CDE 2-mA

Standard sensor for the measurement of chlorine dioxide without cross-sensitivity by free chlorine. For operation on controllers with 4-20 mA input

Your Benefits

â–     Measured variable: Chlorine dioxide, no cross-sensitivity towards free chlorine

â–     Diaphragm-covered sensor minimises faults caused by changing flow or ingredients in the water

Chlorine dioxide sensors complete with 100 ml of electrolyte​

Note: a mounting kit (order no. 815079) is required for initial fitting of the chlorine dioxide sensors in the in-line probe housingDLG III.

​

Chlorine Dioxide Sensor CDP 1-mA

Sensor for the measurement of chlorine dioxide with a fast response time, for example in bottle-washing systems. For operation on controllers with 4-20 mA input

Your Benefits

â–     Measured variable: Chlorine dioxide without interference caused by surfactants

â–     Diaphragm-covered sensor minimises faults caused by changing flow or ingredients in the water

â–     Fast response time through open-pored diaphragm and external temperature measurement​

​

Chlorine dioxide sensors complete with 100 ml of electrolyte​

Note: a mounting kit (order no. 815079) is required for initial fitting of the chlorine dioxide sensors in the in-line probe housing DLG III.

​

Chlorine Dioxide Sensor CDR 1-mA

Sensor for the measurement of chlorine dioxide for all kinds of water, including hot and contaminated water. Without cross-sensitivity by free chlorine. For operation on controllers with 4-20 mA input

Your Benefits

â–     Measured variable: Chlorine dioxide, without cross-sensitivity towards free chlorine

â–     Diaphragm-covered sensor minimises faults caused by changing flow or ingredients in the water

â–     Resistance to films of dirt by pore-free diaphragm

â–     Operating temperature up to 60 °C (short term) by appropriate sensor materials

​

Note: a mounting kit (order no. 815079) is required for initial fitting of the chlorine dioxide sensors in the in-line probe housing DLG III.

Chlorine Dioxide Sensor CDR 1-CAN

Sensor for the measurement of chlorine dioxide for all kinds of water, including hot and contaminated water. Without cross-sensitivity by free chlorine. For operation on controllers with 4-20 mA input

Your Benefits

â–    Measured variable: Chlorine dioxide, without cross-sensitivity to free chlorine

â–    Diaphragm-covered sensor minimises faults caused by changing flow or ingredients in the water

â–    Resistance to films of dirt by pore-free diaphragm

â–    Operating temperature up to 60 °C (short term) by appropriate sensor materials

â–    Operation on the CAN-bus with all the associated benefits

Contact Us

ProMinent Australia

 

​​​​+61 2 9450 0995

​

​

​

envelope icon new.png
bottom of page