Technical Details​
​
Sensor type CDE 2-mA
â– Measuring ranges 0.01…10 mg/l
â– Temperature 5…45 °C
â– Pressure max. 1.0 bar
â– pH range 4.0…11.0
â– Response time 120 s
​
Sensor type CDP 1-mA
â– Measuring ranges 0.02…2.00 mg/l
â– Temperature 10…45 °C
â– Pressure max. 3.0 bar
â– pH range 5.5…10.5
â– Response time 60 s
​
Sensor type CDR 1-mA
â– Measuring ranges 0.01…10.0 mg/l
â– Temperature 1…55 °C
â– Pressure max. 3.0 bar
â– pH range 1.0…10.0
■Response time 180 s​​
​
Chlorine Dioxide Sensor CDE 2-mA
Standard sensor for the measurement of chlorine dioxide without cross-sensitivity by free chlorine. For operation on controllers with 4-20 mA input
Your Benefits
â– Measured variable: Chlorine dioxide, no cross-sensitivity towards free chlorine
â– Diaphragm-covered sensor minimises faults caused by changing flow or ingredients in the water
Chlorine dioxide sensors complete with 100 ml of electrolyte​
Note: a mounting kit (order no. 815079) is required for initial fitting of the chlorine dioxide sensors in the in-line probe housingDLG III.
​
Chlorine Dioxide Sensor CDP 1-mA
Sensor for the measurement of chlorine dioxide with a fast response time, for example in bottle-washing systems. For operation on controllers with 4-20 mA input
Your Benefits
â– Measured variable: Chlorine dioxide without interference caused by surfactants
â– Diaphragm-covered sensor minimises faults caused by changing flow or ingredients in the water
■Fast response time through open-pored diaphragm and external temperature measurement​
​
Chlorine dioxide sensors complete with 100 ml of electrolyte​
Note: a mounting kit (order no. 815079) is required for initial fitting of the chlorine dioxide sensors in the in-line probe housing DLG III.
​
Chlorine Dioxide Sensor CDR 1-mA
Sensor for the measurement of chlorine dioxide for all kinds of water, including hot and contaminated water. Without cross-sensitivity by free chlorine. For operation on controllers with 4-20 mA input
Your Benefits
â– Measured variable: Chlorine dioxide, without cross-sensitivity towards free chlorine
â– Diaphragm-covered sensor minimises faults caused by changing flow or ingredients in the water
â– Resistance to films of dirt by pore-free diaphragm
â– Operating temperature up to 60 °C (short term) by appropriate sensor materials
​
Note: a mounting kit (order no. 815079) is required for initial fitting of the chlorine dioxide sensors in the in-line probe housing DLG III.
Chlorine Dioxide Sensor CDR 1-CAN
Sensor for the measurement of chlorine dioxide for all kinds of water, including hot and contaminated water. Without cross-sensitivity by free chlorine. For operation on controllers with 4-20 mA input
Your Benefits
â– Measured variable: Chlorine dioxide, without cross-sensitivity to free chlorine
â– Diaphragm-covered sensor minimises faults caused by changing flow or ingredients in the water
â– Resistance to films of dirt by pore-free diaphragm
â– Operating temperature up to 60 °C (short term) by appropriate sensor materials
â– Operation on the CAN-bus with all the associated benefits